Pitzen Road Fire: Water Supply Challenge

Fire trucks

Fire operations in rural and nonhydranted areas always add additional factors that, if not planned for, can have a significant impact on the outcome of an incident. For the McHenry Township Fire Protection District (MTFPD), located northwest of Chicago, Illinois, prior planning, establishment of new procedures, and training for these types of events led to a successful outcome at a significant fire.

On January 6, 2019, at 1147 hours, the MTPFD responded to a reported structure fire at 3904 N. Pitzen Road in the village of Johnsburg, Illinois. The house was a large, two-story, wood-frame home approximately 2,500 square feet and built in the early 1970s. It included a full basement. There was one exposure, another three-story house about 25 feet from the fire building, on the B side.

RELATED FIREFIGHTER TRAINING

Prepare to Ensure a Sufficient Water Supply

Doing the Job with Limited Resources in Small Departments

Throw Back to Basics: Rural Water Supply

Assessing Rural Water Supply: A Geospatial Approach

Initial reports indicated that a person could be trapped inside. While companies were en route, the Johnsburg Police Department arrived and confirmed that there was a fire. The first-arriving Engine (E1242) found heavy smoke conditions and fire in Division B. The house was about 150 feet off the roadway, in a valley along Pistakee Bay. There was an approximate 30-foot drop in elevation from the roadway to the front of the house; the rear of the home backed up to Pistakee Bay. Winds coming off the bay were up to 21 miles per hour; the temperature was 35°F.

Strategy and Tactics

Because of the length of the driveway and the distance from the road, E1242’s crew pulled a 2½- to 1¾-inch skid load. They found the exterior porch at the Division A/D corner fully involved. An extended size-up revealed smoke-stained windows on all sides of the house and heavy smoke conditions throughout the structure.

After extinguishing the exterior fire, E1242 could see fire through the windows at the A/D corner. They found a set of stairs on the exterior leading to the basement and could see heavy fire swirling in the basement.

Battalion 12 (Battalion Chief Kevin Sears) arrived and established Pitzen Road Command. He designated E1242 as the Fire Attack group, assisted by E1245, and upgraded the alarm to a Mutual-Aid Box Alarm System (MABAS), a multistate organization for structuring and providing mutual aid, of which the MTFPD is a part. The MABAS box alarm brought in an additional engine, two tenders, a truck, a squad, an ambulance, and two outside chief officers representing eight surrounding communities.

The view of the house from the Division A/D corner.

(1) The view of the house from the Division A/D corner. [Photo by Dave Reid, McHenry Township (IL) Fire Protection District.]

As E1242 began an initial attack, conditions inside the building rapidly deteriorated. Heavy smoke was venting from the cellar door in Division B, and fire was now venting from the gable vent in Division A. Fire Attack reported heavy fire in the attic.

A major concern for the incident commander (IC) was that the conditions visible from the exterior were not matching the reports from interior companies. At this point in the operation, attack lines were operating on both the first and second floors, yet conditions visible from the exterior indicated fire in the basement, on the first and second floors, and in the attic. The offensive fire attack was changed to a defensive attack. An emergency evacuation was ordered, all companies were removed from the building, and a personnel accountability report was conducted.

As additional companies arrived and the command structure was further developed, command was transferred to Chief Tony Huemann and the initial IC (Battalion 12) became Operations. Other chief officers were assigned to Water Supply, Safety, and coverage of the rest of the fire district.

Later during the fire, crews transitioned to some offensive fire attack by laddering the second-floor porch in Division C. From there, they entered to pull ceiling and attack the fire.

Water Supply

Approximately 40 percent of the fire district’s 56 square miles is a nonhydranted area, and this fire was in one of those areas. The initial dispatch to fires in a nonhydranted area includes one of the district’s three tenders. The initial dispatch for this fire included MTFPD Tender 1273 and a tender from the Spring Grove Fire Protection District as part of automatic aid.

The road in front of the structure was a narrow, sloping, dead-end road. There was limited area to place portable tanks, and all tenders had to enter and leave past the fire structure. Engine 1242 set up its portable tank at the front of the engine. When the first tender, TE1272, arrived, it positioned in front of the portable tank and began a nursing operation.

The first-arriving tender established a nursing operation on the roadway in front of the fire scene.

(2) The first-arriving tender established a nursing operation on the roadway in front of the fire scene. (Photo by Tim Olk.)

Because of the sloping terrain and narrow access on the road in front of the house, 500 feet of five-inch supply line was laid to establish a second portable tank site approximately two blocks to the north at the intersection of Pitzen Road and Lewis Lane. MTFPD Engine 1243 established that site with two portable tanks.

Because of the number of tenders needed to support the fire attack, two separate fill sites were set up. The first was at the Bald Knob boat marina, where we used a dry hydrant the department installed several years ago. That hydrant was capable of providing up to 800 gallons per minute (gpm) to refill the numerous tenders. Later in the incident, an engine from the Fox Lake Fire Protection District was also used to draft from the bay to help cut down on the turnaround time of the tenders.

The second fill site was across the street from Bald Knob and directly on the Fox River. A mutual-aid engine from the Fox River Grove Fire Protection District established that site.

During the course of the operation, more than 30 tender fills were accomplished; more than 100,000 gallons of water were used in the fire attack. We never lost the water supply during the entire fire operation.

The home experienced significant damage; however, companies were able to retrieve several items of value to the homeowner.

The primary fill site at the boat marina used a combination of a dry hydrant and drafting from Pistakee Bay.

(3) The primary fill site at the boat marina used a combination of a dry hydrant and drafting from Pistakee Bay. (Photo by Tim Olk.)

Water Supply Planning and Procedures

The MTFPD’s standard operating guidelines for rural water supply operations stipulate that the first-arriving tender establish a nursing operation for the attack engine. We refer to this as “burying the tender.” Typically, the tender will pull past the attack engine and establish a water supply through a three-inch supply line. A second three-inch supply line is stretched from the attack engine back to the tender to refill the tender once a separate water supply is established. The tender will remain in that position for the duration of the incident. Later-arriving engines and tenders then establish a regular rural water supply operation using portable tanks. All MTFPD engines have 1,000-gallon booster tanks, and all three tenders carry 3,500 gallons of water.

Each of the MTFPD’s seven engines carries two 10-foot sections of hard-suction hose. In addition, each engine has mounted on the front bumper a six-foot section of lightweight hard suction attached to a low-level strainer. Each of the three tenders and three of the engines carry 2,100-gallon portable tanks.

Each level of MABAS alarm upgrade brings in an additional two tenders along with other fire apparatus, support units, and chief officers. The fire was upgraded to the fourth-alarm level, which resulted in 10 tenders being on the scene.

Training

Because of the large nonhydranted area that is protected, the department makes a significant commitment to rural water supply training, and members completed more than 1,200 hours on the topic in the past two years. This training is organized and conducted by the department’s full-time training instructor; hands-on drills are emphasized. Some of the topics covered annually include the following: initial tender nursing operations, setting up for rural water supply operations, dry hydrant use, drafting, tender shuttles, use of floating docks, use of portable tanks, and communications between the driver/engineer. In addition, all new members receive training on rural water supply as part of the department’s very extensive probationary firefighter training program.

Lessons Learned

The fact that there was never a loss of water supply during the six-hour fire is a testament to the training, experience, and hard work of the engineers, officers, and firefighters assigned to the water supply operation. There were several occasions where quick thinking or a “plan B” was needed; each time, they reacted quickly and solved the problem.

Some of the other lessons learned include the following:

  • Not all departments carry hard suction on their engines. This became a factor when the first mutual-aid engine assigned to one of the fill sites lacked this equipment. Similarly, we found that not all tenders that responded had fire pumps. Both of these items should be considered when planning for mutual- or automatic-aid response.
  • A standard radio procedure for MABAS departments is to assign a separate fireground radio channel for the water supply operation. With four separate sites as part of the operation, this proved crucial.
  • The dry hydrant is on private property at a boat marina. The MTFPD has worked over the years to maintain a good working relationship with the property owner. The department performs annual maintenance on the dry hydrant and had recently completed it a few months before the fire. This helped ensure that it operated properly that day.
  • Multiple fill sites were needed to provide for the water supply needs. Prior identification of the possible sites proved valuable.

The majority of the structure was saved because of the aggressive work by the crews. Additionally, the amount of planning, the establishment of formal water supply procedures, and training on rural water supply played key roles.


RUDY HORIST is a 37-year veteran of the fire service and a deputy chief for the McHenry Township (IL) Fire Protection District. He serves as vice-chairman of the Illinois Fire Chiefs Association Volunteer & Combination Officer Committee and is an FDIC International workshop presenter and a member of its Educational Advisory Board.

Hand entrapped in rope gripper

Elevator Rescue: Rope Gripper Entrapment

Mike Dragonetti discusses operating safely while around a Rope Gripper and two methods of mitigating an entrapment situation.
Delta explosion

Two Workers Killed, Another Injured in Explosion at Atlanta Delta Air Lines Facility

Two workers were killed and another seriously injured in an explosion Tuesday at a Delta Air Lines maintenance facility near the Atlanta airport.