Firefighter Fatality Report Released on WI Theater Fire LODD

NIOSH Releases Firefighter Fatality Reports on Training Deaths and Other Recent LODDs

The National Institute for Occupational Safety and Health (NIOSH) recently released a report on the death of a volunteer firefighter following the collapse of a bowstring roof at theater fire in Wisconsin earlier this year. Two other firefighters were also injured in the fire at the historic Abby Theatre in Abbotsford.

On March 4, 2012, a 34-year-old male volunteer lieutenant lost his life at a theatre fire after the roof collapsed, trapping him inside the theatre. At approximately 1215 hours, an on-duty patrol officer (also chief of the victim’s fire department) radioed dispatch for a structure fire. The first-due fire department arrived on scene, set up operations on the A-side of the structure, and directed the incoming mutual aid department (the victim’s department) to the rear of the structure. No fire was visible from the rear. Both departments attacked the theatre fire from opposite sides (A-side and C-side) of the structure establishing their own incident commander/officer-in-charge, fireground operations, and accountability systems. The first-due fire department initially fought the fire defensively from the A-side, while the victim and two additional firefighters (FF1 and FF2) entered through the C-side, advancing a hoseline until they met A-side firefighters near the theatre’s lobby (the area of origin). The first due fire department eventually placed an elevated master stream into operation, directing it into the lobby and then onto the roof while firefighters were operating inside. Roof conditions deteriorated until the roof collapsed into the structure trapping the victim, FF1, and FF2. FF1 and FF2 recalled speaking with the victim immediately following the collapse, but nothing was heard from the victim following the activation of a personal alert safety system device. All three were eventually located, removed from the structure, and transported to a local hospital, but the victim had already succumbed to his injuries.

The report listed several contributing factors to the line-of-duty death:

  • Initial arriving units not establishing/performing/implementing an incident management system, an overall incident commander, an incident action plan (IAP), and a 360-degree situational size-up
  • Risk management principles not effectively used
  • Fireground and suppression activities not coordinated
  • Fireground communications between departments not established
  • Incident safety officer (ISO) role ineffective
  • Rapid intervention crew (RIC) procedures not followed and/or implemented
  • Bowstring roof truss construction not recognized by departments
  • Fire burned undetected within the roof void space for unknown period of time
  • Uncoordinated master stream operations
  • Location of victim following roof collapse not immediately known.

It also made several key recommendations, including:

  • Fire departments should ensure that an effective incident management system is established with a designated incident commander not involved with fire suppression activities
  • Fire departments should ensure that a complete situational size-up is conducted on all structure fires
  • Fire departments should use risk management principles at all structure fires
  • Fire departments should work together to develop mutual aid standard operating procedures for fireground operations that support interagency operability and accountability and train on those procedures
  • Fire departments should ensure that the incident safety officer (ISO) position, independent from the incident commander, is appointed and effectively utilized at every structure fire meeting the requirements within NFPA 1521, Standard for Fire Department Safety Officer
  • Fire departments should ensure that a rapid intervention crew (RIC) is readily available, on scene, and prepared to respond to firefighter emergencies.

Read the entire report at http://www.cdc.gov/niosh/fire/reports/face201208.html.

NIOSH firefighter fatality reports can provide critical incidents into what went wrong at deadly incidents. More of these reports can be accessed at http://www.cdc.gov/niosh/fire/.

Hand entrapped in rope gripper

Elevator Rescue: Rope Gripper Entrapment

Mike Dragonetti discusses operating safely while around a Rope Gripper and two methods of mitigating an entrapment situation.
Delta explosion

Two Workers Killed, Another Injured in Explosion at Atlanta Delta Air Lines Facility

Two workers were killed and another seriously injured in an explosion Tuesday at a Delta Air Lines maintenance facility near the Atlanta airport.