BY TOM BRENNAN

For the past few columns, I have tried to recall some of the “What did you mean by that U?” or “Oh yeah, but we don`t do that here!” comments I have received from time to time throughout the country. This month, we continue.

The nozzle has made it to the landing outside the door to the third-floor rear apartment of a four-story multiple dwelling. What do you do with the 50 to 70 feet of hose needed to “make” that apartment?

Well, contrary to the sarcastic remarks, there is more than one solution or place to put it. The main thought here is, Why is it there and how will you need to use it when the apartment door is opened and rapid attack is attempted? The secret of great nozzle attack is movement. The nozzle team must move rapidly through the apartment–as rapidly as the fire permits. If the fire slows you down, that is one thing. But if the snag on advance is from the poor hose layout, that is a crime. If there is a half landing- type staircase with a window on the outside wall (one half landing below the fire floor), provide a large opening. (I am not getting into the “break it or not” argument here)–enough of an opening to pass a large loop of “extra” hose out for a smooth return to the fire floor during the advance.

If the public hall is large, this loop can be laid on the landing on the same plane as the fire door. Or, if the hall is small, force the door to the front apartment and have the firefighter assigned the nozzle calmly “walk” it into the apartment as far as he can and turn around and bring the nozzle back to the fire door. In all these cases, you should have enough hose smoothly laid out to “do the job.” And this is also a great layout for operations above the fire floor should fire extend there. Snags, kinks, and knots are virtually eliminated, and a much more quiet and professional operation begins.

Note: Taking the additional hose up the staircase above the fire floor is not a good idea in these combustible dwelling occupancies. The second line is responsible for the floor above the fire, and its extinguishing operation will hamper and impede the progress of the line in the fire apartment as the first line will stop the smooth advance of operations above the fire floor.

When, then, would stretching the extra (needed) hose “up” the staircase above the fire and returning the nozzle to the fire floor door, forming a “gravity-fed” loop of sufficient hose, be a good idea?

The answer is, it would be efficient and safe to do so IF (1) the building has a standpipe connection within an enclosed staircase–as is found in high-rise dwelling buildings and (2) you are using the standpipe outlet on the floor below the fire for primary hoseline supply and (3) the hallway door is closed and the fire condition found does not prevent you from bringing what is left of the three lengths (at least) that you connected up the staircase and back down again to the fire floor. It is the most rapid advance you can provide for the 150 feet of hose you just connected–especially if it is 212-inch hose.

Another reason: Your backup line is coming from another standpipe outlet. Your fire line will be “out of the way” for the advance of the second line–at least until you get it on the public hall and down to the fire apartment. See? It all fits! KISS.

We are the first-arriving engine. The second engine is responsible for stretching large-diameter hose to us and providing water supply.

This is a mess in departments with sufficient hydrant water supply. It means that a hydrant stream will supply hydrant residual pressure from an average of 250 feet away from the pumping engine. It also means that there will be two engine units at the same location. It means that the access to the fire building is heretofore blocked from one end of the street (given that the engine parking scenario is at least away from in front of the building). It means that one pumping engine is not more than a useless bus at this location. The opposite side of the fire will also be locked because hose larger than 212 inch “dropped” to serve as a hydrant supply is never dressed to the side of the street–with water supplied it snakes for the entire face of the asphalt.

Better: First engine drops (any configuration of securing couplings and adapters and fittings to a hydrant here is permissible and certainly parochial). The second engine, by communication, arrives at that location and, after a few one-person connections, pumps the supply line. The members leaving to walk to the fire building to secure a second line dress the large-diameter hose at the only time that they can–when it is dry. Pressures are sufficient on the fireground, and water is established virtually uninterrupted. The street is clear for positioning additional equipment. In-line pumping was never meant to be anything more than a 400-foot hydrant connection!

TOM BRENNAN has more than 35 years of fire service experience. His career spans more than 20 years with the City of New York (NY) Fire Department as well as four years as chief of the Waterbury (CT) Fire Department. He was the editor of Fire Engineering for eight years and currently is a technical editor. He is co-editor of The Fire Chief`s Handbook, Fifth Edition (Fire Engineering Books, 1995). He is the recipient of the 1998 Fire Engineering Lifetime Achievement Award. You can e-mail him at tfb111@aol.com.

Hand entrapped in rope gripper

Elevator Rescue: Rope Gripper Entrapment

Mike Dragonetti discusses operating safely while around a Rope Gripper and two methods of mitigating an entrapment situation.
Delta explosion

Two Workers Killed, Another Injured in Explosion at Atlanta Delta Air Lines Facility

Two workers were killed and another seriously injured in an explosion Tuesday at a Delta Air Lines maintenance facility near the Atlanta airport.