55th Anniversary of Chicago’s Our Lady of Angels School Fire Nears

Shortly before the end of classes on December 1, 1958, a fire broke out at the Our Lady of Angels Elementary School in Chicago, IL. The fire left 95 dead and many others seriously injured. This fire, which occurred 55 years ago, is still one of the deadliest school fires in the history of the United States.

“Poor fire protection design was a major contributing factor to the significant number of deaths and injuries,” said Chris Jelenewicz, engineering program manager with the Society of Fire Protection Engineers. “Additionally, many lives were lost because the fire burned out of control for a considerable amount of time before the building occupants and the fire department were notified that an emergency existed in the building.”

At the time of the fire about 1,600 children — grades kindergarten through grade eight occupied the two-story brick and wood joist building.

The fire started in the basement at the bottom of one of the building’s interior stairways. The open stairway did not have fire-rated doors at the top of the stairs. As a result, the fire spread quickly up the stairs and into the second floor corridors.

“Once the fire started, the stairway effectively became a pathway for the hot smoke and deadly gases to spread quickly up the stairs and throughout the second floor corridors,” said Jelenewicz. “This prevented the occupants from exiting through the corridors which was the only safe escape route.”

The fire department rescued many children with ground ladders or by catching those who jumped out the windows. Despite these efforts, many of the children died in their classrooms and others were forced to jump out windows to their deaths.

Moreover, the building was not equipped with a fire sprinkler system.

“Because of the delay in notification, the lack of adequate fire protection systems, and the unprotected stairs, the occupants just didn’t have enough time to get out alive,” said Jelenewicz.

As a result of this fire, many building requirements were enhanced to make schools safer from fire. Some of these requirements include the installation of fire alarm and automatic fire suppression systems and increasing the frequency of exit drills.
    
“The Our Lady of Angels Fire reminds us of the threat that is posed by fire and the importance of designing buildings that keep people safe from fire,” said Jelenewicz. “The fact of the matter, however, is that today schools are much better protected. This is in large part due to the fire safety strategies and systems designed by fire protection engineers that make our world safer from fire.”

What is a Fire Protection Engineer?
According to the Society of Fire Protection Engineers, a fire protection engineer applies science and engineering principles to protect people, homes, workplaces, the economy and the environment from the devastating effects of fires. Fire protection engineers analyze how buildings are used, how fires start and grow, and how fires affect people and property. They use the latest technologies to design systems to control fires, alert people to danger, and provide means for escape. Fire protection engineers also work closely with other professionals, including engineers of other disciplines, architects, state and local building officials, and local fire departments to build fire safe communities. Fire protection engineers are in high demand. The number of available jobs far exceeds the supply.

More information on SFPE can be found at www.sfpe.org.

Hand entrapped in rope gripper

Elevator Rescue: Rope Gripper Entrapment

Mike Dragonetti discusses operating safely while around a Rope Gripper and two methods of mitigating an entrapment situation.
Delta explosion

Two Workers Killed, Another Injured in Explosion at Atlanta Delta Air Lines Facility

Two workers were killed and another seriously injured in an explosion Tuesday at a Delta Air Lines maintenance facility near the Atlanta airport.